Radian Specifications

The Outback Radian Inverter is a great Off-Grid, Grid-Interactive and Grid-Tie Inverter.

Electrical Specifications
Nominal DC Input Voltage 48 VDC
Continuous Output Power at 25 °C 8000 VA
AC Output Voltage 120/240 VAC
AC Output Frequency 60 Hz
Continuous AC Output Current at 25 °C 33.3 AAC at 240 VAC
Waveform True Sinewave
CEC Weighted Efficiency 90%
Total Harmonic Distortion (Typical) <5% THD, Max single voltage harmonic <2%
Output Voltage Regulation +/- 2%
Maximum Output Current (1 ms peak) 100 AAC at 240 VAC, 200 AAC at 120 VAC
Maximum Output Current (100 ms RMS) 70.7 AAC at 240 VAC
Overload Capability (100 ms surge) 16.97 kVA at 240 VAC
Overload Capability (5 second) 12 kVa
Overload Capability (30 minute) 9 kVa
Idle Consumption - Invert mode, no load 30 Watts
AC Input Voltage Range (Adjustable) (L1 or L2) 70 - 140 VAC
AC Input Frequency Range 54 - 66 Hz
Grid-Interactive Voltage Range (Default) (L1 or L2) 108 - 132 VAC
Grid-Interactive Frequency Range (Default) (L1 or L2) 59.3 - 60.5 Hz
AC Input Current (Maximum) 50 AAC at 240 VAC
Battery Charger Maximum AC Input 30 AAC at 240 Vac
Battery Charger Maximum DC Output 115 ADC
DC Input Voltage Range 40 - 64 VDC
DC Input Current at Rated Power 200 ADC
Maximum DC Input Current on Surge 424.2 ADC
Auxiliary Output 0.7 ADC at 12 VDC
Auxiliary Relay 10 A at 250 VAC/30 VDC (resistive)

 

Mechanical Specifications
Inverter Dimensions (H x W x D) 28 x 16 x 8.7" (71.1 x 40.6 x 22.2 cm)
Shipping Dimensions (H x W x D) 14.5 x 34.5 x 21" (36.8 x 87.6 x 53.3 cm)
Inverter Weight 125 lbs (56.8 kg)
Shipping Weight 140 lbs (63.6 kg)
Accessory Ports Remote Temperature Sensor and MATE3/HUB Communications
Non-volatile Memory Yes
Field Upgradable Firmware Yes
Chassis Type Vented